					 110V CNC high pressure fried chicken stove liquefied 
		petroleum gas 
				 
			 | 
		 
		
			| 
			 | 
		 
		
			| 
			 | 
		 
		
			| 
			 | 
		 
		
			| 
				 
					The gas 
		energy-saving fried chicken stove has the advantages of automatic 
		temperature control, automatic ignition, gas heating flameout 
		protection, fast heating, low gas consumption, stable performance and 
		reliable quality. It is suitable for hotels, canteens and individual 
		businesses. 
				 
			 | 
		 
		
			
				   
			 | 
		 
		
			| 
				 
					Parameters  
				 
			 | 
		 
		
			
				
					
						
							| 
								 
									Rated 
				voltage  
								 
							 | 
							
								 
									110V  
								 
							 | 
							
								 
									Fryer 
				oil capacity  
								 
							 | 
							
								 
									35KG  
								 
							 | 
						 
						
							| 
								 
									Rated 
				frequency  
								 
							 | 
							
								 
									50Hz-60Hz  
								 
							 | 
							
								 
									Productivity  
								 
							 | 
							
								 
									25KG/h  
								 
							 | 
						 
						
							| 
								 
									Rated 
				input power  
								 
							 | 
							
								 
									150W  
								 
							 | 
							
								 
									Temperature control range  
								 
							 | 
							
								 
									20℃~ 250℃  
								 
							 | 
						 
						
							| 
								 
									Gas 
				type  
								 
							 | 
							
								 
									liquefied petroleum gas  
								 
							 | 
							
								 
									Timing 
				range  
								 
							 | 
							
								 
									0-99 minutes  
								 
							 | 
						 
						
							| 
								 
									Rated 
				air pressure  
								 
							 | 
							
								 
									2.8Kpa  
								 
							 | 
							
								 
									 Dimensions  
								 
							 | 
							
								 
									104*52*116cm (40.94x20.47x45.67 Inches)  
								 
							 | 
						 
						
							| 
								 
									Gas 
				consumption  
								 
							 | 
							
								 
									1.0KG/h  
								 
							 | 
							
								 
									Rated 
				working pressure  
								 
							 | 
							
								 
									0.0833Mpa  
								 
							 | 
						 
					
				 
			 | 
		 
		
			| 
				 
					Main Working 
		Principle  
				 
			 | 
		 
		
			| 
				 
					By means of the 
		automatic control of microcomputer programs and the combination with 
		electronic automatic temperature controller, the ignition and start-up 
		of the combustion system, temperature rise and heating, automatic 
		constant temperature, flameout protection alarm, and safety protection 
		of the stove body are achieved.  
				 
			 | 
		 
		
			| 
				Product 
		Features  
			 | 
		 
		
			
				   
			 | 
		 
		
			| 
				  1. Using gas fire to generate heat, stable and efficient.  
					 
 2. The capacity of the pot is about 45L. You can fry 6-8 ducks at a time.  
				 
 3. Thickened aluminum cover, durable, no rust.  
					 
 4. With sealing ring, good sealing effect, easy to clean.  
				 
 5. Triple safety valve protection. Automatic exhaust valve, manual exhaust valve, safety valve. Effective and safe pressure relief. Combined with a kilo screw, very strong.  
					 
 6. Intelligent digital temperature control. The buttons on the control panel are simple and easy to use for novices.  
				 
 7. Complimentary frying basket, handle, gas low pressure valve.  
					 
 8. The lower part of the pot body is allocated with an oil basin, which has large space and is more convenient for oil pouring.  
				 
  
			 | 
		 
		
			| 
				 
					Installation 
		Method  
				 
			 | 
		 
		
			| 
				 
					1. Place the 
		fried chicken stove steadily and check whether all components have been 
		damaged during transportation. If there are any problems, these problems 
		must be solved before use.  
				 
				
					2. The 
		equipment cannot be placed near wooden walls, flammable materials cannot 
		be placed around the equipment, smoke exhaust and ventilation facilities 
		must be installed indoors, and fire extinguishers must be available 
		nearby to ensure safety. (The gas inlet connector is located on the 
		lower portion of the interior of the electrical box, and the electrical 
		box door needs to be opened in the installation process.)  
				 
				
					3. Connect the 
		equipment to the  LPG tanks with a gas hose 
		and the equipment gas inlet reliably, and fix both ends of the hose with 
		clamps. There should be no gas leakage in the gas transmission section, 
		and no sundries can be piled up around it. Only low-pressure valves are allowed, and the use 
		of high-pressure and medium pressure valves is prohibited.  
				 
				
					4. The power 
		connection should be carried out by electrical professionals, and the 
		power supply voltage should be consistent with the rated voltage on the 
		label. The power cord must be connected to a power socket with a leakage 
		protector and overload protection device.  
				 
				
					5. The machine 
		shell is equipped with a bolt for the grounding mark, and the user must 
		firmly connect the protective grounding wire that complies with safety 
		regulations.  
				 
				
					  
				 
			 | 
		 
		
			| 
				 
					Precautions  
				 
			 | 
		 
		
			| 
				 
					1. Do not touch 
		the exhaust outlet to avoid scalds in the frying process.  
				 
				
					2. Only the 
		electrical professionals are allowed to open the electrical box.  
				 
				
					3. Children are 
		strictly prohibited from approaching the device in the using process so 
		as to avoid scalds.  
				 
				
					4. For safety 
		production, the machine must be connected to a safety grounding device, 
		otherwise it cannot be used.  
				 
				
					5. Do not 
		directly contact the heat source around the gas source, and do not store 
		flammable materials to avoid accidents.  
				 
				
					6. After 
		filling the fryer with oil, be sure to check whether the fasteners on 
		the fryer cover are secure in place before heating, and then tighten the 
		seal to prevent the injury caused by detachment in the using process.  
				 
				
					7. Before the 
		fried food is taken out, the exhaust valve must be opened to release the 
		air. After the air in the fryer is completely discharged, the pressure 
		gauge pointer should return to the "0" position. After one minute, the 
		fryer cover can be opened.  
				 
				
					8. It is 
		strictly prohibited to hit the handle, cover and fryer mouth with hard 
		objects to prevent accidents.  
				 
				
					9. When the 
		cover does not work, it can be closed, but it must not be tightened so 
		as to prevent long-term compression and aging deformation of the sealing 
		ring.  
				 
				
					10. Clean away 
		the impurities in the safety valve pipeline timely to prevent blockage. 
		The rated oil quantity should be maintained in the fryer, otherwise the 
		normal production will be affected.  
				 
				
					11. When the 
		customer stops using the machine, the power supply must be cut off and 
		the angle valve of the gas source must be closed.  
				 
			 | 
		 
		
			| 
				 
					  Warning:Only 
		low-pressure valves are allowed, and the use of high-pressure and medium 
		pressure valves is prohibited.  
				 
			 | 
		 
		
			
				     
			 | 
		 
		
			
				     
			 | 
		 
		
			
				     
			 | 
		 
		
			| 
				Item Number: 220529  
			 | 
		 
		
			| 
			 | 
		 
		
			| 
				 
					You can make 
		order with no worry.  
Any concern just feel free to let us know, we'll reply in 24 hours in 
		normal condition. 
Handling Time: Shipping is usually made in 1-3 business days after 
		payments cleared. Orders are processed from Monday-Friday; Not on the 
		weekends & public holidays. 
Warranty: 6 months' warranty for the machines, not for the consumables.  
We stand behind our products all the item, so even if your warranty 
		period has expired, you can still seek for service or technical support 
		from us with low cost.  
				 
			 | 
		 
	
 
	 
	 |