Rk7112 Withstand Hi-Pot Tester 110V/AC5KV

RK7112 series voltage withstand test instruments are for general- purpose HV test operation. It can be widely used for voltage withstand test in electrician’s assistant instrument,rubber-wooden facility,voltage convertor,wires , power meter, motor, power supply plug, cables and all kinds of electronic and electric products. As the launch of the national security standard, Voltage  withstand  instrument  has  become  one  of  necessary  withstand  test instruments to the radio and electronic products manufacturer.
Operating request: Environmental temperature 0~40

                           Relative humidity≤75%

https://topseller365.com/data/prd/142/014/1.jpg


parameter

Model RK7112
Advantage 5 sets of data can be set
Insulating test
Input single-phase47-63HZ,115V/230V AC±15%
Output
frequency
Range:50Hz/60Hz Optional
Slow rise Range:0.1--999.9s,0.1s/Step
Output
ripple
Sine wave THD
<2%(Crest Factor)>1.3<1.5
Test time Range:0.2--999.9s,0.1s/Step 0=continuity
Input Voltage (Power) 110V
ARC
Detector
Range: Level 1-9 can be set

 

Details

https://topseller365.com/data/prd/142/014/5.jpg https://topseller365.com/data/prd/142/014/6.jpg

https://topseller365.com/data/prd/142/014/2.jpg

Calibration

The instrument has been carefully calibrated before they go out, completely conform to the
requirements of the index of the instrument. The instrument for at least a yearly calibration,
calibration precision of the instrument must be better than 0.5%, to ensure that the instrument
can continue after calibration is precision of the instrument should be.

Calibration of instrument and equipment

Voltmeter: Measuring range above the 0-6000 V AC
Ammeter :Measuring range from 0-15 mA AC above
Load resistance :500 k Ω - 800 k Ω, more than 0.5 WATT

Item Included(142014)

1×Withstand Voltage TestEquipment 
1×High Voltage Test Line
1×Ground Line
1×Power Cord

 